New York City · Domestic Hot Water
Operating Cost Calculator
Compare central steam, natural gas, heat pump, and electric resistance domestic hot water, with an optional heat-reclaim scenario. Operating costs only.
Domestic Hot Water · NYC
Annual Operating Cost Comparison
Annual comparison
CalculatingAnnual hot-water equivalent
–gallons
Annual heat demand
–million BTU
Effective annual system COP
–incl. entered electric backup
Cold / typical / warm year — all options
| Weather | Heat pump | Gas | Steam | Electric resistance | Reclaim + backup | Heat pump COP |
|---|
All scenarios use the current model and inputs. Weather changes the water-heating requirement and heat pump efficiency. Utility prices remain constant.
Compare different heat pump COPs
| Fixed COP | Cold year | Typical year | Warm year |
|---|
This table intentionally holds COP fixed for each row to isolate COP sensitivity, while allowing the monthly incoming-water temperature to vary by weather scenario. Backup percentage still applies.
Monthly detail · Typical year
| Month | Outdoor °F | Incoming °F | COP* | Heat MMBTU | HP $ | Gas $ | Steam $ | Resistance $ | Reclaim MMBTU | Reclaim + backup $ |
|---|
*COP column shows estimated compressor COP. Annual effective COP also includes electric resistance share. Monthly outdoor temperatures are illustrative monthly averages; using average weather instead of hourly data is approximate.
Scope and important assumptions
Operating energy only. Does not include purchase/installation of equipment, storage tanks, space heating, financing, or maintenance. Rate inputs can include annual utility fixed/demand charges but no time-of-use or steam tariff tiers. Gas heat and steam heat are calculated from useful hot-water energy with entered efficiencies. Heat pump monthly COP is interpolated between specified temperature points; below 10°F and above 68°F, boundary COP is held constant (no invented extrapolation). Ice Air test data is at 140°F supply, so estimates at other supply temperatures require manufacturer confirmation. Capacity/sizing, defrost, and automatic auxiliary heating are not modeled; enter a backup percentage if applicable. Hot-water equivalent gallons are at the demand reference temperature (default 125°F); supply temperature does not change fixture heating load. Manufacturer COP data may be invalid at other supply temperatures.
Cooling heat reclaim (scenario only, off by default). When enabled, a hypothetical reclaim setup preheats the domestic water. Available reclaim is the entered cooling load x full-load hours x 1.25 (a generic heat-of-compression factor, not measured equipment performance) x the entered utilization %, spread across months by cooling need and capped at each month's hot-water demand and at the energy needed to reach the reclaim preheat temperature. The utilization % covers coincidence, storage and timing and is an assumption, not a verified figure. The remaining demand is priced on the chosen backup system at the same rates and efficiencies. Reclaim pump electricity and any entered added chiller energy are included; any entered cooling-side savings credit is subtracted. Added compressor energy from higher condensing temperature is not modeled automatically. Reclaim only runs while there is cooling demand, and retrofit feasibility for the specific AC / chiller equipment is not established.
Cooling heat reclaim (scenario only, off by default). When enabled, a hypothetical reclaim setup preheats the domestic water. Available reclaim is the entered cooling load x full-load hours x 1.25 (a generic heat-of-compression factor, not measured equipment performance) x the entered utilization %, spread across months by cooling need and capped at each month's hot-water demand and at the energy needed to reach the reclaim preheat temperature. The utilization % covers coincidence, storage and timing and is an assumption, not a verified figure. The remaining demand is priced on the chosen backup system at the same rates and efficiencies. Reclaim pump electricity and any entered added chiller energy are included; any entered cooling-side savings credit is subtracted. Added compressor energy from higher condensing temperature is not modeled automatically. Reclaim only runs while there is cooling demand, and retrofit feasibility for the specific AC / chiller equipment is not established.